Skip to main content
5W4C1F-40LL4/0

5W4C1F-40LL4/0 Endress Hauser United States Sales

If you are looking for a reliable supplier where you can purchase the 5W4C1F-40LL4/0 industrial product, you are in the right place. ONRION sells all product groups belonging to the Endress Hauser brand in the United States market, with fast delivery times and competitive prices.

5W4C1F-40LL4/0
Product5W4C1F-40LL4/0
BrandEndress Hauser
HS Code90261021
CountryUnited States
Request a price
Delivery time: Determined at the time of quotation
VISA Mastercard Bank Transfer

Technical Specification

Promag W 400, 5W4C1F, DN150 6"

Electromagnetic flowmeter
Flanged version
The specialist for the industry of
water/wastewater
International approvals for drinking
water
Mounting length according to DVGW/ISO
Corrosion-resistant transmitter housing.
Compact and separate housing identical
for the compact/remote version.
:: Versatile flowmeter designed for the water industry
:: Constant accuracy, even without
straight lengths upstream/downstream (0D) and
without pressure loss (option)

Additional specifications
AA Approval: Non-Ex zone
D Execution: Rotating flange
L Supply: AC 100...240V, AC/DC 24V
H Output; input: 4-20mA HART + Pulse/Frequency
+ TOR
P Housing: Separate, coated aluminum, IP66/67, type 4X
3 Cable for separate version: 20m/60ft cable reel
+ signal
D Electrical connection: Thread NPT1/2
Q Coating: PTFE 90°C
A14 Process connection: Cl.150, stainless steel, rotating
flange ASME B16.5
G Electrodes: 1.4435/316L, pointed
A Flow calibration: 0.5%

Details
Display format 1 value, max. size
Value 1 display Volume flow
Value 2 display None
Value 3 display None
Value 4 display None
Display damping 0.00000 s
Totalizer 1
Unit m3
Operating mode totalizer Net flow total
Failure mode Stop
Totalizer 2
Unit m3
Operating mode totalizer Forward flow total
Failure mode Stop
Totalizer 3
Unit m3
Operating mode totalizer Reverse flow total
Failure mode Stop
Curr. output 1 Volume flow
Current span 4...20 mA NAMUR
Value 0/4 mA 0.00000 m3/h
Value 20 mA 150.00000 m3/h
Default mode current output
Max.
Damping output 1 1.00000 s
Operating mode Pulse

Pulse assignment Volume flow
Pulse value (per pulse) 0.02500 m3
Pulse width 100.000 ms
Default mode output
pulse
No pulses