DIC-4-006-E-0000-03 Demag United States Sales
If you are looking for a reliable supplier where you can purchase the DIC-4-006-E-0000-03 Dedrive Compact STO frequency inverter, you are in the right place. ONRION sells all product groups belonging to the Demag brand in the United States market, with fast delivery times and competitive prices.
Request a price
Delivery time:
Determined at the time of quotation
VISA
Mastercard
Bank Transfer
Technical Specification
Replaced Material No 16040084
Demag Dedrive Compact STO frequency inverter
Digital two-point inverter with voltage intermediate circuit
for one and four-quadrant operation with integrated brake chopper
for resistance braking.
Integrated safety function “Safely switched off moment”
(Safe Torque Off, STO) in accordance with EN 61800-5-2. Meets the
requisitions
Cat.3, PLd according to EN ISO 13849-1 and SIL2 according to IEC 61508.
Technical data:
Line voltage: 3 x 380 - 480 V (+10/-15%)
Line frequency: 50/60 Hz (+10/-10%)
Motor shaft power: 2.20 kW
Output voltage: 3 x 0 - line voltage V
Output frequency: 0 - 300 Hz depending on switching frequency
Output current: 5.8 A at 2 to 8kHz
Overload factor at 2 and 4kHz: 1.5 for 60 s; 2.0 for 10 s
(cycle 10 min)
Modulation frequencies: 2, 4, 8, 12, 16 kHz
(Note the power reduction
Integrated safety function “Safely switched off moment”
(Safe Torque Off, STO) in accordance with EN
61800-5-2. Meets the requirements of Cat.3, PLd according to
EN ISO 13849-1 and SIL2 in accordance with IEC 61508.
Technical data:
Line voltage: 3 x 380 - 480 V (+10/-15%)
Line frequency: 50/60 Hz (+10/-10%)
Motor shaft power: 2.20 kW
Output voltage: 3 x 0 - line voltage V
Output frequency: 0 - 300 Hz depending on switching frequency
Output current: 5.8 A at 2 to 8kHz
Overload factor at 2 and 4kHz: 1.5 for 60 s; 2.0 for 10 s (cycle 10
min)
Modulation frequencies: 2, 4, 8, 12, 16 kHz (current reduction
notice
Protection class: IP 20
operating temperature: 0 - 40 °C
Installation height: 0 - 1000 m
dimensions: 60/250/175 mm width/height/depth
Installation position: vertical
Net weight: approx. 1.7 kg
Technical data at operating point
Line voltage: 3 x 400 V
Output current: 5.8 A at 40 °C ambient temperature
and 4 kHz modulation frequency
Overload factor: 1.5 for 60 s (cycle 10 min.)
2.0 for 10 s (cycle 10 min.)
Operating temperature: 0 °C/40 °C
Installation height: 0/1000 m
Specification:
Type: Dedrive Compact STO DIC-4-006-E-0000-03
- Keypad KP 500 (control unit)