Skip to main content
RS3120-44A80H2011

RS3120-44A80H2011 CD AUTOMATION United States Sales

If you are looking for a reliable supplier where you can purchase the RS3120-44A80H2011 industrial product, you are in the right place. ONRION sells all product groups belonging to the CD AUTOMATION brand in the United States market, with fast delivery times and competitive prices.

RS3120-44A80H2011
ProductRS3120-44A80H2011
BrandCD AUTOMATION
HS Code90328900
CountryUnited States
Request a price
Delivery time: Determined at the time of quotation
VISA Mastercard Bank Transfer

Technical Specification

RS3120-44A80H20X1

Three-phase thyristor controller series REVO S
Type RS3120-44A80H2011
G-No.:
REVOS-A-B-C-D-E-F-G-H-I-K-L
K=X User manual, german=Standard
(A) Load current (HeightxWidthxDepth) Weight
Without fuse (30A to 40A)
030: 30A (121x108x125mm) 1.32 kg
035: 35A (121x108x125mm) 1.32 kg
040: 40A (121x108x125mm) 1.32 kg
With fuse (30A to 40A)
030: 30A (121x108x185mm) 1.83 kg
035: 35A (121x108x185mm) 1.83 kg
040: 40A (121x108x185mm) 1.83 kg
Integrated fuse
060: 60A (273x187x170mm) 7.00 kg
075: 75A (273x187x170mm) 7.00 kg
090: 90A (273x187x170mm) 10.60 kg
120 120A (273x281x170mm) 10.60 kg
150 150A (273x281x170mm) 10.60 kg
180: 180A (273x281x170mm) 10.60 kg
210: 210A (273x281x170mm) 10.60 kg
300 300A (520x262x270mm) 22.00 kg

350 350A (520x262x270mm) 22.00 kg
400 400A (520x262x270mm) 22.00 kg
450 450A (520x262x270mm) 22.00 kg
500 500A (520x262x270mm) 22.00 kg
800 800A (560x411x270mm) 51.60 kg
( B) Maximum load voltage
4: 480V
6: 600V
7: 690V
(C) Mains voltage
0: none (without HB and/or analog input, up to 210A)
4: 12-24V ac/dc (for devices with HB) up to 210A
1: 90-135V for devices >210A
2: 180-265V for devices >210A
3: 238-330V for devices >210A
5: 342-528V for devices >210A
6: 540-759V for devices >210A
7: 540-759V for devices >210A
(D) Input
S: SSR
V: 0...10Vdc, 60A to 700A
A: 4....20mA, 60A to 700A
(E) Operating mode
Z: ZC Zero Crossing
4: Burst Firing, BF4
8 Burst Firing; BF8
6: Burst Firing, BF16
(F) Feedback
0: none
(G) Fuses and options
0: no fuse (up to 40 A)
F: IFH (integrated fuse and fuse holder)
Y: IFH + CT (current transformer)
H: IFH + CT + HB (partial load fault alarm)
X: IFH + CT + HB + "Flat wiring system" for devices up to 40A.
(H) Fan
0: none (up to 40A)
1: with 115V from 60A
2: with 230V from 60A (Standard)
3: with 24V from 60A
(I) UL
0: without UL
L: with UL (as soon as available)
(K) User manual
0: none
1: Italian
2: English
3: German (as available)

(L) Version
1: Standard