teco ci 95 base 60 Technotrans United States Sales
If you are looking for a reliable supplier where you can purchase the teco ci 95 base 60 Reliable temperature control unit of the base.line product line., you are in the right place. ONRION sells all product groups belonging to the Technotrans brand in the United States market, with fast delivery times and competitive prices.
Technical Specification
Main features:
- Membrane keypad and 7 segment display
- Stainless-steel "longlife" heating cartridge
- Durable low-wear peripheral pump
- Mould draining via suction (reversal of direction of rotation)
- Unit with a stainless steel tank, system pressure-free
Technical data teco ci 95 base 60
- Operating fluids, heat transfer media: water
- Max. circulation temperature: 95 °C
required water quality
https://www.technotrans.com/products/filtration-and-separation/wasserqualitaet
Heater: continuous with solid states relay
- Heating capacity: 9 kW
Cooling: indirect, WT 7/03
- Cooling regulation: solenoid valve
- Cooling capacity: 75 kW
- at circulation medium temperature: 90 °C
- at cooling water temperature: 15 °C
Process pump bi-frequency: WP 601
- Max. delivery rate at 60Hz: 60 l/min
- Max. delivery pressure at 60Hz: 3,8 bar
- Max. delivery rate at 50Hz: 45 l/min
- Max. delivery pressure at 50Hz: 3,0 bar
Control
- basicControl: 32-bit controller
Bi-frequency multi-voltage device suitable for
- operating voltage: 380-415V/50cycl./3Ph+Pe
-and: 440-480V/60cycl./3Ph+Pe
Connections
- Auswahl Alternative 1
- Power supply cable: 3,0 m with CEE pug 16A
- Auswahl Alternative 2
- Power supply cable: 3,0 m main cable without CEE-plug
- Circulation medium connection: supply/return G 1/2"
- Cooling water connection: supply/return G 1/2"
- Cooling water pressure: 3-4 bar
- Control cabinet protection type: IP 54
Dimensions (LxWxH): 662x280x611 mm
-Weight: 55 kg
- covers: RAL 260 40 45 LED blue
- housing/front panel: RAL 7012 basalt grey
Max. ambient temperature: 40 °C
Noise level: DIN 45635T1, LpA 1m< 70 db(A)
Standard equipment:
Operation:
- Membrane keypad and 7 segment display
Heater:
- Stainless steel "longlife" heating cartridge
Pump technology:
- Durable low-wear peripheral pump
Measuring system/alarm indication:
- Electronic temperature measurement in the feed flow
- Acoustic and visual alarm signal
Additional features:
- Unit with a stainless steel tank, system pressure-free
- Parts that contact the medium are made of corrosion-resistant materials
- Cooling via a solenoid valve
- Good accessibility for maintenance work due to removable cover plates
- Interface port on the front of the unit
- Optimised positioning flexibility due to compact design
- IP 54 control cabinet
- y-strainer in the cooling medium feed line
- Mould draining via suction (reversal of direction of rotation)
The standard equipment is extended by the following options:
(Options may replace standard equipment mentioned above)
- 11.70 - Profibus Interface
- 14.50 - y-strainer in circulation medium return
The standard equipment is extended by the following special options:
- Special Voltage 400 V/60 cycles/ 3 Ph