Technical Specification
TMU-S025-317B-A00-A0-10/UMC4-B11A00H
50000001
Coriolis mass flowmeter
Model code sensor: TMU-S025-317B-A00-A0-10-0-H
Model code measurement converter: UMC4-B11A00H
Process data:
Display range [kg/h]: 3000
Medium name: Molasses
Density [kg/m3]: 1350
Viscosity [mPas]: 1
Process temperature [°C]: 60 (max 150)
Process pressure [pe bar]: 4
Flow direction: left-right
Sensor data:
Parts in contact with the medium: 1.4571 (316Ti) /1.4404 (316L)
Standard measurement range: min. 0 - 3,000 kg/h
max. 0-30,000 kg/h
Process connection: DN40 PN40 Form B1 DIN/EN1092
Pressure resistance: 40 bar
Sensor housing: stainless steel housing 1.4301 (304)
Housing pressure resistance: 0 bar
Sensor protection class: IP66 (EN60529)
Heating/cooling: none
Heating/cooling connection: without
Measurement converter arrangement: built-in measurement converter
Temperature range: -20 to 100°C
Sensor connection: -
Approval: none
Mass flow calibration: standard, 3-point
Calibration density: none
Overall length: 600 mm
PED: CAT II
Type: UMC4
Mounting type: built-in measurement converter
Sensor connection: -
Cable screw thread: M20x1.5
Display and control unit: built-in control unit
Display language: English
Supply voltage: 90-265V AC; 50/60 Hz
Current output 1 (passive): 0/4-20 mA with HART® protocol
mass flow rate, temperature
volume flow rate, density
Current output 2 (passive): 0/4-20 mA
mass flow rate, temperature
volume flow rate, density
Pulse output 1:.. Imp/kg passive
Status output 2: passive
Forward/backward measurement
alarm
MIN/MAX flow
MIN/MAX density
MIN/MAX temperature
Approval: none
Ignition protection type signal outputs: without
Ambient temperature: -20 to +60°C
Protection class measurement converter: IP66 (EN60529)
Characteristics:
Measurement uncertainty (measurement range): ± 0.1% of the measured value
plus zero point stability
Repeatability: ± 0.05% of measured value
± 1/2 zero point stability
Pressure loss: ~ 0.02 bar at 3000 kg/h